This article was previously published under Q97685 SYMPTOMS
This information applies to both Microsoft DoubleSpace and Microsoft
DriveSpace. For MS-DOS 6.22, use DRVSPACE in place of DBLSPACE for commands
and filenames.
The AutoSketch 3.0 installation program provides incorrect default settings
if you install AutoSketch on a DoubleSpace-compressed drive. Even if you
correct the settings, the installation may fail. You may receive an error
message indicating that a math coprocessor could not be found.
WORKAROUND
To work around this problem, disable the mounting of the compressed volume
file (CVF), install AutoSketch on the host drive, remount the CVF, and then
copy the program to the compressed drive. Detailed steps for this procedure
are listed below for both MS-DOS 6.0 and MS-DOS 6.2.
NOTE: These procedures assume drive H is your host drive; if it is not,
replace H with the actual host drive letter.
MS-DOS 6.0- Make sure there is enough space on the host drive to install
AutoSketch. If not, use DoubleSpace to increase the size of your host
drive. (For more information, refer to the "Using DoubleSpace to Manage
Compressed Drives" section of Chapter 5 in the Microsoft MS-DOS 6
"User's Guide." This section includes information on the Change Size
command.)
- At the MS-DOS command prompt, type the following commands, pressing
ENTER after each line:
copy c:\command.com h:\
copy c:\dos\attrib.exe h:\
attrib -s -h -r h:\dblspace.bin
ren h:\dblspace.bin temp.bin
- Reboot the computer by pressing CTRL+ALT+DEL.
- Install AutoSketch on drive C (the uncompressed host drive, which
was previously drive H).
- At the MS-DOS command prompt, type the following commands, pressing
ENTER after each line:
ren h:\temp.bin dblspace.bin
attrib +s +h +r h:\dblspace.bin
- Reboot the computer by pressing CTRL+ALT+DEL.
- Type the following command and press ENTER:
xcopy h:\sketch3\*.* c:\sketch3 /s
(When prompted, indicate that this is a directory.)
- Type the following command and press ENTER:
- Run the AutoSketch program to see if the installation on drive C
was successful.
- Quit AutoSketch.
- At the MS-DOS command prompt, type the following commands,
pressing ENTER after each line:
deltree h:\sketch3
del h:\sketch3.bat
MS-DOS 6.2- Make sure there is enough space on the host drive to install AutoSketch.
If not, use DoubleSpace to increase the size of your host drive. (For
more information, refer to the "Using DoubleSpace to Manage Compressed
Drives" section of Chapter 5 in the Microsoft MS-DOS 6 "User's Guide."
This section includes information about the Change Size command.)
- Reboot the computer by pressing CTRL+ALT+DEL.
- When the "Starting MS-DOS..." prompt is displayed, press CTRL+F5.
- Install AutoSketch on drive C (the uncompressed host drive, which
was previously drive H).
- Reboot the computer by pressing CTRL+ALT+DEL.
MORE INFORMATION
For more information about AutoSketch 3.0, contact Autodesk Retail
Products.
AutoSketch 3.0 is manufactured by Autodesk, a vendor independent of
Microsoft; we make no warranty, implied or otherwise, regarding this
product's performance or reliability.