MSIPX Stops when Switching from 802.3 to ETHERNET2 (96614)






This article was previously published under Q96614

SUMMARY

This article describes switching from 802.3 to an ETHERNET2-type network stops operation of MSIPX stack.

SYMPTOMS

MSIPX stack does not work.

CAUSE

By default, NetWare is set to use 802.3. If you change to ETHERNET2, you need to change settings elsewhere in the network.

RESOLUTION

Make one of the following changes:

Change Network Adapter Protocol in Control Panel

  1. From Control Panel, select the Network icon.
  2. Select Adapter, select Setup, then choose the Protocol button.
  3. Select IPX protocol to make the Settings button active.
  4. Choose Settings, then select the option that changes 802.3 to Std ETHERNET.

For Windows for Workgroups

There is a switch in the NetWare dialog box,
(CONTROL_PANEL\NETWORK\ADAPTERS\SETUP\PROTOCOLS\NOVELL_IPX\SETTINGS\AD
      PTER_MEDIA_TYPE)
				
that lets you choose Novell/ETHERNET or ETHERNET_II (DIX). The Novell/ETHERNET setting is equivalent to 802.3. Change it to ETHERNET_II (DIX).

For LAN Manager

Use the Novell ECONFIG utility to switch to ETHERNET II (DIX).

On the client:

  • If the driver is ODI, under the Link Driver section of NET.CFG you must define the allowable frame formats (ETHERNET_II and ETHERNET_802.3) as well as which IPX is to be used. (For example: Protocol IPX 8137 ETHERNET_II.)
  • If the driver is not ODI, use the ECONFIG utility (for example: ECONFIG IPX.COM SHELL:E).
Novell's ODI drivers are designed to default to 802.2 for the drivers below:

When using these drivers, you must use either the 802.2 frame type on your server or change the frame type for the workstation in your NET.CFG (or SHELL.CFG) file.
      EXOS      COM     20850 05-12-92  11:24a
      NE1000    COM     19455 09-08-92   3:10p
      NE1500T   COM     28758 05-14-92   1:42p
      NE2       COM     19839 10-27-92   2:38p
      NE2_32    COM     19551 10-27-92   2:39p
      NE2000    COM     19715 09-08-92   3:10p
      NE2100    COM     28756 05-14-92   1:42p
      NE3200    COM     26248 10-08-92   9:56a
				
If you want to continue to use the 802.3 frame type, place the following two lines in the NET.CFG (or SHELL.CFG) file:

Link Driver <drivername>
Frame Ethernet_802.3

If you want to use the NE2000.COM driver, replace <drivername> with NE2000. Be sure to indent the second line and to place a carriage return after the second line.

On a 3.11 Server

  1. In the AUTOEXEC.NCF, load the frame type for the board, and give it a name such as LOAD 3C503 FRAME=ETHERNET_II NAME=ETHER.
  2. Bind IPX to ETHER net=<net number> on a 2.x server.
  3. Run ECONFIG.

Modification Type: Major Last Reviewed: 7/30/2001
Keywords: KB96614