WFWG: MS-DOS Applications May Return FCB UNAVAILABLE Error (95877)
The information in this article applies to:
- Microsoft Windows for Workgroups 3.1
This article was previously published under Q95877 SYMPTOMS
When running some earlier MS-DOS-based applications with Windows for
Workgroups running in enhanced mode and from a remote network drive,
you may receive the following error message:
FCB UNAVAILABLE
Abort, Fail?
WORKAROUND
To work around this error message, do either of the following:
- Run the MS-DOS-based application from a local drive.
-or-
- Start the Real Mode Redirector by typing net start workstation at an MS-DOS command prompt. Run the
application with Windows for Workgroups running in standard mode.
-or-
- Start the Full Redirector by typing net start full at an MS-DOS command prompt.
STATUS
Microsoft has confirmed this to be a problem in Windows for Workgroups
version 3.1. This problem does not occur in later versions of the product.
Modification Type: | Major | Last Reviewed: | 9/26/1999 |
---|
Keywords: | KB95877 |
---|
|