PC MAPI: Simple MAPI Version 3.2.0.4081 Update (95522)
The information in this article applies to:
- Microsoft Mail for Windows 3.0b
- Microsoft Mail for Windows 3.2
This article was previously published under Q95522 SUMMARY
Microsoft provides replacements for the Simple MAPI files, included with
versions 3.0b and 3.2 of Microsoft Mail for PC Networks, for both Microsoft
C and Microsoft Visual Basic. The replacement files provide additional
enhancements to the original Mail technical reference disk.
For complete information about obtaining and installing the Simple MAPI
files, see the following sections:
- To download the updated files
- To update your technical reference disk
- To use the technical reference manual files
- To update your MAPI.DLL and FRAMEWORK.DLL files
- To use the Autosend application or source code
MORE INFORMATION
This update includes the following files:
Filename | Description
----------------------------------------------------------------------
TECHDISK.EXE | Mail technical reference disk
TECHDOCS.EXE | Mail technical reference manual
MAPI.DLL | Messaging Application Programming Interface (MAPI)
| dynamic link library
FRAMEWRK.DLL | Framework layer dynamic link library
SAMPLE.EXE | Sample Simple MAPI application for sending mail
| automatically. Source files included.
The Simple MAPI files included on the technical reference disk allow
application developers to include messaging capabilities in their
applications' user interfaces. Support is provided for both Microsoft
C and Microsoft Visual Basic.
This update contains TECHDISK.EXE, a replacement for the Mail technical
reference disk included with versions 3.0b and 3.2 of Microsoft Mail for
Windows. This replacement disk provides additional enhancements to
the original Mail technical reference disk and includes the following
modifications for versions 3.0b and 3.2 of Microsoft Mail for Windows:
- MAPI.H has been modified to be strictly ANSI compatible, and no
longer causes warnings on Warning Level 4 with the Microsoft C
version 7.0 compiler.
- The sample Visual Basic Simple MAPI application has been modified
to compile when you use Microsoft Visual Basic version 2.0.
This update also contains TECHDOCS.EXE, an electronic version of the Mail
technical reference manual included with version 3.2 of Microsoft Mail for
Windows.
This update also includes the latest MAPI.DLL and FRAMEWRK.DLL files, and a
sample Visual Basic program called Autosend (included in the SAMPLE.EXE
file) that sends mail at specific times or intervals. The code for this
application is included to allow additional capabilities such as checking
mail response time between postoffices.
This update also contains MAPI.DLL, a replacement for the MAPI.DLL file
included with versions 3.0b and 3.2 of Microsoft Mail for Windows. This
replacement file provides additional enhancements to the original MAPI.DLL
file and resolves the following problems that can occur when you are using
versions 3.0b and 3.2 of Microsoft Mail for Windows:
- Deleting a message in a shared folder does not function as
expected; the message in the folder is deleted, but the header
still appears. If you select the header to bring up the message,
Mail for Windows returns a dialog box that says "The message cannot
be accessed." Also, if you change a message in any way, the message
becomes inaccessible.
- Reply, Reply All, and Forward commands on customer messages in
shared folders fail if these commands are called from Mail for
Windows. This problem occurs because the client hands off the
temporary message ID of the shared folder, instead of the permanent
shared-folder message ID.
NOTE: For this problem to be resolved, two files must be updated:
the MAPI.DLL file (included in this update) and the MSMAIL.EXE file
(update included in MAILUPD.EXE on the MSL).
- To correctly launch e-forms, Microsoft Electronic Forms Designer
requires that the message type it gives to Simple MAPI be preserved
in the delivered message. However, the message type is not encoded
in WINMAIL.DAT by default, so it is lost across gateways.
Therefore, the message is received and displayed as a note rather
than as a Microsoft electronic form.
- Custom forms that did not include their own textize maps
could not use the provided default print/save functionality.
NOTE: To fix this problem, MSSFS.DLL (update included in MSSFS.EXE
on the MSL) version 3.2.4081 or later must be used in conjunction
with the MAPI.DLL included in this update.
This update also contains FRAMEWRK.DLL, a replacement for the FRAMEWRK.DLL
file included with versions 3.0b and 3.2 of Microsoft Mail for Windows.
This replacement file resolves the following problem that can occur when
you use versions 3.0b and 3.2 of Microsoft Mail for Windows:
- When you execute the MAPIAddress() function, an "Out of Memory"
error can occur. This problem occurs because a second MAPI session
is being started and closed, and the MAPIAddress() function is then
executed in the first session.
To Download the Updated FilesThe following file is available for download from the Microsoft Download Center:
For additional information about how to download Microsoft Support files, click the following article number to view the article in the Microsoft Knowledge Base:
119591 How to Obtain Microsoft Support Files from Online Services
Microsoft scanned this file for viruses. Microsoft used the most current virus-detection software that was available on the date that the file was posted. The file is stored on security-enhanced servers that help to prevent any unauthorized changes to the file.
After you download MAPIUPD.EXE to a clean directory, run it (by typing
mapiupd at the MS-DOS prompt) to extract the contents of the file.
You should receive the following files:
MAPI.DLL ( 54,208 bytes, dated 02/01/95, 2:31 A.M.)
TECHDISK.EXE (216,727 bytes, dated 09/17/93, 8:00 A.M.)
TECHDOCS.EXE (289,006 bytes, dated 09/17/93, 8:00 A.M.)
FRAMEWRK.DLL (221,168 bytes, dated 05/06/93, 7:00 A.M.)
SAMPLE.EXE (334,884 bytes, dated 09/17/93, 8:00 A.M.)
README.TXT
To update your technical reference disk- At the MS-DOS command prompt, type the following and press ENTER
copy <drive>:\techref\disk\techdisk.exe <destination>
where <drive> the drive and directory where you ran the self-extracting
MAPIUPD.EXE file and <destination> is the drive and directory where
your Simple MAPI files currently reside. For example, if you ran the
self-extracting file from the TEST directory on drive D, and your
Simple MAPI files are located in the MAILEXE\TECHREF directory on
drive C, type the following command:
copy d:\test\techdisk.exe c:\mailexe\techref - At the MS-DOS command prompt, type the following and press ENTER
<destination>\techdisk.exe -d
where <destination> is the drive and directory where your Simple
MAPI files currently reside. For example, if your Simple MAPI files
are located in the MAILEXE\TECHREF directory on drive C, type the
following command:
c:\mailexe\techref\techdisk.exe -d - At the MS-DOS command prompt, type the following and press ENTER
copy <mailexe>\setup.inf <mailexe>\setupinf.old
where <mailexe> is the complete path to the directory containing
the Microsoft Mail for Windows SETUP.EXE program. For example, if
SETUP.EXE is located in the MAILEXE directory on drive C, type the
following command:
copy c:\mailexe\setup.inf c:\mailexe\setupinf.old - Using any text editor, edit the SETUP.INF file. In the [MsMail
System] section, replace the following line
1, mapi.dll,,,, 1993-05-26, !DECOMPRESS,, OLDER, !READONLY
,,,,, SHARED, ,,,,, 54352,,,, 3.2.0.4037,
with:
1, mapi.dll,,,, 1995-02-01, !DECOMPRESS,, OLDER, !READONLY
,,,,, SHARED, 54208,,,, 3.2.0.4081
Save the file and close the text editor.
NOTE: For these changes to affect the entire network, each existing
user must run Setup again.
To use the technical reference manual files
At the MS-DOS command prompt, type the following commands and press
ENTER after each line
md <harddrive>:\<destination>
copy <drive:>\techref\doc\techdocs.exe <destination>
<destination>:\techdocs.exe
where <harddrive> is the local hard disk or network drive, <drive> is
the drive and directory where you ran the self-extracting MAPIUPD.EXE
file, and <destination> is the path where you want the technical reference
manual files to reside. For example, if you ran the self-extracting file
from the TEST directory on drive D, and you want the files to reside in the
C:\TECHDOCS directory, type the following command:
md c:\techdocs
copy d:\test\techdocs.exe c:\techdocs
c:\techdocs\techdocs.exe
The technical reference manual files are in Word for Windows 2.0
format. Read the README.TXT file in the directory where the technical
reference files reside.
To update your MAPI.DLL and FRAMEWORK.DLL files
NOTE: To fix the problem with MAPI.DLL version 3.2.4081, you must do one
of the following steps:
- Recompile all user[ASCII 146]s custom-form generating applications supplying
the custom form a new message class name.
-or-
- To replace the old textize map with a new one, you need to create a
new mail message file (MMF) for every user.
At the MS-DOS command prompt, type the following and press ENTER
copy< drive>:\*.DLL< destination>
where <drive> is the drive and directory where you ran the self-extracting
MAPIUPD.EXE file and <destination> is the drive and directory where your
MAPI.DLL and FRAMEWRK.DLL files currently reside. For example, if you ran
the self-extracting file from the TEST directory on drive D, and your
MAPI.DLL and FRAMEWRK.DLL files are located in the MAILEXE directory on
drive C, type the following command:
copy d:\test\*.DLL c:\mailexe To use the Autosend application or source code- At the MS-DOS command prompt, type the following commands and press
ENTER after each line
md <harddrive>:\<destination>
copy <drive>:\sample\sample.exe <destination>
<destination>:\sample.exe
where <harddrive> is the local hard disk or network drive, <drive>
is the drive and directory where you ran the self-extracting
MAPIUPD.EXE file, and <destination> is the path where you want the
sample application files to reside. For example, if you ran the self-
extracting file from the TEST directory on drive D, if you want the
files to reside in the C:\SAMPLE directory, type the following command:
md c:\sample
copy d:\test\sample.exe c:\sample
c:\sample\sample.exe - At the MS-DOS command prompt, type the following commands and press
ENTER after each line to use the Autosend application
copy <samplepath>:\*.vbx c:\<windir>
copy <samplepath>:\*.dll c:\<windir>\system
where <samplepath> is the drive and directory where the sample
application resides and <windir> is the path to the Windows
directory. For example, if the sample application is in the
C:\SAMPLE directory and your Windows directory is C:\WINDOWS, type
the following commands:
copy c:\sample\*.vbx c:\windows
copy c:\sample\*.dll c:\windows\system
Run the sample application from Windows. To use the source code,
you must use the Professional Edition of Microsoft Visual Basic
version 2.0 or later.
Modification Type: | Minor | Last Reviewed: | 8/4/2004 |
---|
Keywords: | kbdownload kbdownload kbgraphxlinkcritical KB95522 |
---|
|