This article was previously published under Q94290 SYMPTOMS
You may encounter the error message, "Module has changed; must reset"
after which the program ends and returns to design mode. Setting
a watch point contributes to the problem.
In general, this problem occurs under the following conditions:
- A global, form, or module-level watch point is set.
- The watch point refers to a Visual Basic object such as a form or
control.
- The watch point is evaluated from break mode when a modal form is
showing.
STATUS
Microsoft has confirmed this to be a bug in Microsoft Visual Basic
version 2.0 for Windows. This bug was corrected in Microsoft Visual
Basic version 3.0 for Windows.