FIX: You may receive a Scriptor component error message when you add the /3GB switch to the Boot.ini file on a Windows Server 2003 SP1-based computer that is running Commerce Server 2002 or Commerce Server 2007 (920352)
The information in this article applies to:
- Microsoft Commerce Server 2002
- Microsoft Windows Server 2003 SP1
- Microsoft Commerce Server 2007 Standard Edition
- Microsoft Commerce Server 2007 Developer Edition
- Microsoft Commerce Server 2007 Enterprise Edition
SYMPTOMSConsider the following scenario. Microsoft Commerce Server 2002 or Microsoft Commerce Server 2007 is running on a Microsoft Windows Server 2003 Service Pack 1 (SP1)-based computer. You add the /3GB command-line switch to the Boot.ini file. In this scenario, you may receive a Scriptor component error message in the event log that resembles the following: Event Type: Error
Event Source: Commerce Server 2002
Event Category: None
Event ID: 4104
Date: Date Time: Time User: N/A
Computer: ComputerName Description: Pipeline Error: Component Execution failed for component [0xE] hr: 0x80020003
ProgID: Commerce.Scriptor.1
MscsExecute() failed.
Script invocation failed.
Member not found.
RESOLUTIONTo resolve this problem, install the hotfix that is discussed in Microsoft Knowledge Base article 903648.
For more information, click the following article number to view the article in the Microsoft Knowledge Base:
903648
You receive an error message if you try to start the VBScript engine from a Microsoft C++-based program on a Windows Server 2003 Service Pack 1-based computer
STATUSMicrosoft has confirmed that this is a problem in the Microsoft products that are listed in the "Applies to" section.
Modification Type: | Major | Last Reviewed: | 7/3/2006 |
---|
Keywords: | kbinfo kbtshoot kbprb KB920352 kbAudITPRO kbAudDeveloper |
---|
|