Packard Bell Packmate Requires HIMEM.SYS /m: 1 (92938)
The information in this article applies to:
- Microsoft Windows 3.1
- Microsoft Windows 3.11
This article was previously published under Q92938 SYMPTOMS
To ensure proper operation with Windows 3.1, If you are using Microsoft
Windows on a Packard Bell Packmate 300 SX, 386/33 or 486/33 DX computer,
you may experience general protection faults and memory parity errors in
both Windows-based and MS-DOS-based applications running under Windows.
CAUSE
To ensure proper operation with Windows 3.1, the Packard Bell Packmate
386/33 and 486/33 DX computers require that the A20 handler number 1
is installed. If the /M:1 parameter is not included on the HIMEM.SYS
line in the CONFIG.SYS file, A20 handler number 3 may be incorrectly
installed, which can cause the symptoms above.
WORKAROUND
To correct this problem, change the following line in the CONFIG.SYS
file
DEVICE=<drive><path>HIMEM.SYS
-to-
DEVICE=<drive><path>HIMEM.SYS /M:1
The Packmate 486/33 DX is manufactured by Packard Bell, a vendor
independent of Microsoft; we make no warranty, implied or otherwise,
regarding this product's performance or reliability.
Modification Type: | Major | Last Reviewed: | 10/14/2003 |
---|
Keywords: | KB92938 |
---|
|