Installing WFWG over IBM Lan Server Causes Netbind Error (92881)
The information in this article applies to:
- Microsoft Windows for Workgroups 3.1
- Microsoft Windows for Workgroups 3.11
This article was previously published under Q92881 SYMPTOMS
If you install Windows for Workgroups on a machine that was once an
IBM OS/2 Lan Server client, you may receive a "Netbind" error followed
by an "Undefined Dynalink" error when you start Windows for
Workgroups.
CAUSE
These errors indicate that there are still IBM Lan Server drivers in
the CONFIG.SYS and AUTOEXEC.BAT files.
RESOLUTION
The following lines need to be removed or remarked out (using REM)
from the CONFIG.SYS file:
- Any lines that reference PROTMAN.EXE (Windows for Workgroups uses
PROTMAN.DOS)
- Any lines that reference DXMEOMOD.SYS
In the AUTOEXEC.BAT file, any reference to the Lan Server software
directory in the PATH= statement should be removed.