SYMPTOMS

After you load the NDIS driver for the Thomas Conrad TC6145 card, WORKGRP.SYS may report the following error message:
Parameter Format Not Correct

WORKAROUND

This card may have "compatibility mode." If so, configure the card for compatibility with a card listed in Setup or the Network section of Control Panel.

STATUS

The TC6145 is an older card and is no longer supported by Thomas Conrad. The TC6242 card does not have this problem.

Modification Type:MajorLast Reviewed:10/27/1999