A 32-bit program may not print colors correctly when it is running on a 64-bit version of Windows Server 2003 or on a 64-bit version of Windows XP (919332)
The information in this article applies to:
- Microsoft Windows Server 2003, Standard x64 Edition
- Microsoft Windows Server 2003, Enterprise x64 Edition
- Microsoft Windows Server 2003, Datacenter x64 Edition
- Microsoft Windows Server 2003, Enterprise Edition for Itanium-based Systems
- Microsoft Windows Server 2003, Datacenter Edition for Itanium-based Systems
- Microsoft Windows XP Professional x64 Edition
- Microsoft Windows XP Professional 64-Bit Edition (Itanium)
SYMPTOMSA 32-bit program may not print colors correctly when you print a file on a computer that is running a 64-bit version of Microsoft Windows Server 2003 or a 64-bit version of Microsoft Windows XP.CAUSEThis problem occurs because one of the internal structures of the Graphics Device Interface (GDI) is incompatible with 32-bit programs that run on 64-bit versions of Windows.
The printer driver's DrvQueryColorProfile function receives invalid parameters. Therefore, the printer driver cannot select an ICC profile.RESOLUTIONHotfix informationA supported hotfix is now available from Microsoft, but it is only intended to correct the problem that is described in this article. Only apply it to systems that are experiencing this specific problem. This hotfix may receive additional testing. Therefore, if you are not severely affected by this problem, we recommend that you wait for the next Windows Server 2003 service pack or Windows XP service pack that contains this hotfix. To resolve this problem immediately, contact Microsoft Product Support Services to obtain the hotfix. For a complete list of Microsoft Product Support Services telephone numbers and information about support costs, visit the following Microsoft Web site: Note In special cases, charges that are ordinarily incurred for support calls may be canceled if a Microsoft Support Professional determines that a specific update will resolve your problem. The usual support costs will apply to additional support questions and issues that do not qualify for the specific update in question. PrerequisitesNo prerequisites are required. Restart requirementYou must restart your computer after you apply this hotfix. Hotfix replacement informationThis hotfix does not replace any other hotfixes. File information
The English version of this hotfix has the file attributes (or later file attributes) that are listed in the following table. The dates and times for these files are listed in Coordinated Universal Time (UTC). When you view the file information, it is converted to local time. To find the difference between UTC and local time, use the Time Zone tab in the Date and Time item in Control Panel.Windows Server 2003, x64-based versions, and Windows XP Professional x64 Edition |
Gdi32.dll | 5.2.3790.2703 | 610,304 | 16-May-2006 | 03:03 | x64 | SP1 | SP1QFE | Wgdi32.dll | 5.2.3790.2703 | 285,184 | 16-May-2006 | 03:03 | x86 | SP1 | WOW |
Windows Server 2003, Itanium-based versions, and Windows XP Professional 64-Bit Edition (Itanium) |
Gdi32.dll | 5.2.3790.2703 | 907,776 | 16-May-2006 | 03:05 | IA-64 | SP1 | SP1QFE | Wgdi32.dll | 5.2.3790.2703 | 285,184 | 16-May-2006 | 03:05 | x86 | SP1 | WOW |
STATUSMicrosoft has confirmed that this is a problem in the Microsoft products that are listed in the "Applies to" section.
Modification Type: | Minor | Last Reviewed: | 7/26/2006 |
---|
Keywords: | kbBug kbfix kbQFE kbhotfixserver kbpubtypekc KB919332 kbAudITPRO |
---|
|