You are prompted to continue the software removal process when you use Spuinst.exe and the /passive switch to remove an MDAC update (916647)
The information in this article applies to:
- Microsoft Data Access Components 2.5 SP3
- Microsoft Data Access Components 2.7 SP1
- Microsoft Data Access Components 2.8
- Microsoft Data Access Components 2.8 Service Pack 1 (SP1)
SYMPTOMSConsider the following scenario. You use the Software Update Removal Wizard (Spuninst.exe) to remove software updates. You try to remove any one of the following Microsoft Data Access Components (MDAC) software updates by using Spuinst.exe and the /passive switch: - MDAC253-KB911562-x86-<LANG>.exe
- MDAC271-KB911562-x86-<LANG>.exe
- MDAC28-KB911562-x86-<LANG>.exe
- MDAC282-KB911562-x86-<LANG>.exe
Note In this list, <LANG> is a placeholder for the language. In this scenario, you are prompted to continue the software removal process, even though the /passive switch should not require user interaction. WORKAROUNDTo work around this problem, use the /quiet switch instead of the /passive switch. The installation will be silent, and any required reboots will occur automatically.
Modification Type: | Major | Last Reviewed: | 4/11/2006 |
---|
Keywords: | kbExpertiseInter kbExpertiseAdvanced kbtshoot kbprb KB916647 kbAudDeveloper kbAudITPRO |
---|
|