An advertised program does not run when a user logs on to the SMS 2003 Advanced Client computer (905794)
The information in this article applies to:
- Microsoft Systems Management Server 2003
- Microsoft Systems Management Server 2003 SP1
SYMPTOMSConsider the following scenario. You advertise a program to a Microsoft Systems
Management Server (SMS) 2003 Advanced Client computer. A user logs on to this SMS 2003 Advanced Client computer. In this scenario, the program that you advertised does not run. This
symptom occurs if the following conditions are true: - The Assign immediately after this event setting is configured to Logon for the program's advertisement.
Note The Assign immediately after this event setting is configured by using the Schedule tab in the Advertisement Name Advertisement Properties dialog box. You must click the button to add a mandatory assignment. - The SMS 2003 Advanced Client
computer is running Microsoft Windows 2000, Microsoft Windows XP or a later version of Microsoft Windows.
- A user logs on to the SMS 2003 Advanced Client computer and the following conditions are true:
- The user logs on to the SMS 2003 Advanced Client computer after the computer restarts.
- The user logs on to the SMS 2003 Advanced Client computer before the SMS Agent Host service has started.
- It takes more than one minute from the starting of the
operating system until the scheduler thread in the SMS Agent Host service starts.
RESOLUTIONTo resolve this problem, use either of the following
methods. Method 1To resolve this problem if the SMS 2003 Advanced Client
computer is running Windows 2000, install the hotfix that is described in Microsoft Knowledge Base article number 825666.
For more information about this hotfix, click the following article number to view the article in the Microsoft Knowledge Base:
825666
LastBootUpTime value does not update when you change the time zone
Method 2Use this method if either of the following conditions are true:
- The SMS 2003 Advanced Client
computer is running Microsoft Windows XP or a later version of Microsoft Windows.
- The problem that is described in this article is not resolved after you install the hotfix that is described in Microsoft Knowledge Base article number 825666.
To resolve this problem, edit the
registry on the SMS 2003 Advanced Client computer. To do this, add a REG_DWORD MaxRestartTime registry entry that has a value of 5 to the following registry subkey: HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\CCM\CcmExec Note The value of the MaxRestartTime registry entry is set in minutes.
STATUSMicrosoft
has confirmed that this is a problem in the Microsoft products that are listed
in the "Applies to" section.
| Modification Type: | Major | Last Reviewed: | 10/11/2005 |
|---|
| Keywords: | kbtshoot kberrmsg kbprb KB905794 kbAudITPRO |
|---|
|