CAUSE
This problem may occur if the following conditions are true:
- The device uses the Windows XP inbox driver for the Remote Network Device Interface Specification (RNDIS).
- The device uses the Interface Association Descriptor (IAD) to describe which interfaces belong to the adaptor.
The problem occurs because the Usbccgp.sys driver does not configure all interfaces that are defined in the IAD when the driver handles a URB_FUNCTION_SELECT_CONFIGURATION request. The driver configures only the first interface and does not return valid pipe handles for the remaining interfaces.
RESOLUTION
A supported hotfix is now available from Microsoft, but it is only intended to correct the problem that is described in this article. Only apply it to systems that are experiencing this specific problem. This hotfix may receive additional testing. Therefore, if you are not severely affected by this problem, we recommend that you wait for the next Windows XP service pack that contains this hotfix.
To resolve this problem immediately, contact Microsoft Product Support Services to obtain the hotfix. For a complete list of Microsoft Product Support Services telephone numbers and information about support costs, visit the following Microsoft Web site:
Note In special cases, charges that are ordinarily incurred for support calls may be canceled if a Microsoft Support Professional determines that a specific update will resolve your problem. The usual support costs will apply to additional support questions and issues that do not qualify for the specific update in question.
Prerequisites
Install hotfix 890927 before you install this hotfix.
Restart requirement
You must restart the computer after you apply this hotfix.
Hotfix replacement information
This hotfix does not replace any other hotfixes.
File information
The English version of this hotfix has the file attributes (or later file attributes) that are listed in the following table. The dates and times for these files are listed in Coordinated Universal Time (UTC). When you view the file information, it is converted to local time. To find the difference between UTC and local time, use the
Time Zone tab in the Date and Time tool in Control Panel.
Date Time Version Size File name
---------------------------------------------------------------------------
17-Jun-2005 00:18 5.1.2600.2700 30,744 Usbccgp.sys