PROTOCOL.INI File Open Failure with Stacker (90212)
The information in this article applies to:
- Microsoft Windows for Workgroups 3.1
- Microsoft Workgroup Connections 1.0
This article was previously published under Q90212 SYMPTOMS
If you install Stacker Electronics Stacker version 2.0 after Windows
for Workgroups or Workgroup Connections, you receive the following
error message when you restart (reboot) your computer:
PRO0003E: PROTOCOL.INI file open failure. Unable to open
PROTOCOL.INI.
CAUSE
Stacker correctly copies PROTMAN.DOS, WORKGRP.SYS, and other system
files to the unstacked drive. The problem occurs because the
PROTOCOL.INI file needs to be copied to the original directory on the
unstacked drive.
WORKAROUND
You need to manually copy the PROTOCOL.INI file to the original
directory. After you do this, the PROTOCOL.INI file will be found when
the system starts.
Modification Type: | Major | Last Reviewed: | 10/13/2003 |
---|
Keywords: | KB90212 |
---|
|