LAN Man 2.1 Test Summary (DigiBoard DigiCHANNEL C/X EISA) (89515)






This article was previously published under Q89515

SUMMARY

The following are the test results for the DigiBoard DigiCHANNEL C/X System, EISA Host Adapter multiport communication board. The test was conducted as part of the Microsoft Compatibility Lab (MCL) peripheral test for LAN Manager version 2.1:

MORE INFORMATION

Company

DigiBoard
6751 Oxford St.
Minneapolis, MN 55426
(612) 943-9020

Date Tested

5/19/92

Multiport Communication Board

Model:                 DigiCHANNEL C/X System, EISA Host Adapter
Serial number:         473672
I/O port:              N/A
Memory address:        0D0000h
				

Board Switch Settings

No switches to set on this board.

Other Hardware Supplied

Connector for port board:        DIGICHANNEL C/CON - 16 (DB25)
Part number:                     50000043 REV.F
				

Software and Drivers

OS/2 device driver filename:     XALL.SYS
Date of file:                    11/20/91
Version:                         1.3.2
				

Line Added to CONFIG.SYS

device=c:\digi\xall.sys /a:Q /n:3 /p:5005 /m:D0000 /t:m10
				

Testing Environment

Operating system:        OS/2 1.3
Network:                 LAN Manager 2.1
Test platforms:          486/33 16 MB RAM
Bus specification:       EISA
Network topology:        Ethernet
Server file system:      HPFS
				

Final Test Results

Test Focus                    Pass    Anomalies and/or Workarounds
----------                    ----    ----------------------------
Installation                   Yes    The server and all RAS clients
                                      are using a null modem Cable
                                      running at 9600 baud. Higher
                                      baud rates are available using
                                      the DigiBoard, but are not
                                      recommended for the RAS service.

Remote Access admin            Yes
Remote Access server           Yes
Network functionality          Yes
Stress                         Yes
Named pipes                    Yes
				

Modification Type: Major Last Reviewed: 7/30/2001