LAN Man 2.1 Test Summary (DigiBoard DigiCHANNEL C/X MCA) (89513)






This article was previously published under Q89513

SUMMARY

The following are the test results for the DigiBoard DigiCHANNEL C/X System, MCA Host Adapter multiport communication board. The test was conducted as part of the Microsoft Compatibility Lab (MCL) peripheral test for LAN Manager version 2.1:

MORE INFORMATION

Manufacturer

DigiBoard
6751 Oxford St.
Minneapolis, MN 55426
(612) 943-9020

Date Tested

5/19/92

Multiport Communication Board

Model:                 DigiCHANNEL C/X System, MCA Host Adapter
Serial number:         551773
I/O port:              F1F0h
Memory address:        FC0000h
				

Board Switch Settings

No switches on this board.

Other Hardware Supplied

Connector for port board:        DIGICHANNEL C/CON - 16 (DB25)
Part number:                     50000043 REV.F
				

Software and Drivers

OS/2 device driver filename:     XALL.SYS
File date:                       11/20/91
Version:                         1.3.2
				

Line Added to CONFIG.SYS

device=c:\digi\xall.sys /a:Q /n:3 /p:f1f0 /m:fc0000 /t:m10
				

Testing Environment

Operating system:        OS/2 1.3
Network:                 LAN Manager 2.1
Test platforms:          386/25 6 MB RAM
Bus specification:       MCA
Network topology:        Ethernet
Server file system:      FAT
				

Final Test Results

Test Focus                  Pass     Anomalies and/or Workarounds
----------                  ----     ----------------------------

Installation                Yes      The server and all RAS clients

                                     are using a null modem cable
                                     running at 9600 bps. Higher
                                     transmission rates are available
                                     using the DigiBoard, but are not
                                     recommended for the RAS service.

Remote Access Admin         Yes
Remote Access Server        Yes
Network Functionality       Yes
Stress                      Yes
Named Pipes                 Yes
				

Modification Type: Major Last Reviewed: 7/30/2001
Keywords: KB89513