You receive an error message when you try to start SNA Manager on a server that is running Microsoft Host Integration Server 2004 (883850)
The information in this article applies to:
- Microsoft Host Integration Server 2004
INTRODUCTIONWhen you log on to a server that is running Microsoft Host Integration Server 2004, and then you try to start SNA Manager, you receive the following error message: The instruction at "0x60b84a7e" referenced memory at "0x0000000c". The memory could not be "read". The following event is also logged: Event Type: Error
Event Source: Application Error
Event Category: (100)
Event ID: 1000
Date: 7/7/2004
Time: 12:09:56 PM
User: N/A
Computer: <COMPUTER_NAME>
Description:
Faulting application mngcli.exe, version 6.0.1700.0, faulting module snatrc.dll, version 6.0.1700.0, fault address 0x00004a7e.
For more information, see Help and Support Center at http://support.microsoft.com.
Data:
0000: 41 70 70 6c 69 63 61 74 Applicat
0008: 69 6f 6e 20 46 61 69 6c ion Fail
0010: 75 72 65 20 20 6d 6e 67 ure mng
0018: 63 6c 69 2e 65 78 65 20 cli.exe
0020: 36 2e 30 2e 31 37 30 30 6.0.1700
0028: 2e 30 20 69 6e 20 73 6e .0 in sn
0030: 61 74 72 63 2e 64 6c 6c atrc.dll
0038: 20 36 2e 30 2e 31 37 30 6.0.170
0040: 30 2e 30 20 61 74 20 6f 0.0 at o
0048: 66 66 73 65 74 20 30 30 ffset 00
0050: 30 30 34 61 37 65 004a7e
CAUSEThis problem occurs when you log on to the server, and you do not have administrator permissions.
Modification Type: | Major | Last Reviewed: | 9/22/2006 |
---|
Keywords: | kbtshoot kbinfo KB883850 kbAudDeveloper kbAudITPRO |
---|
|