AS/400 Folders Not Recognized in Windows 3.1 386-Enhanced Mode (87977)



The information in this article applies to:

  • Microsoft Windows 3.1
  • Microsoft Windows 3.11
  • Microsoft Windows for Workgroups 3.1
  • Microsoft Windows for Workgroups 3.11

This article was previously published under Q87977

SYMPTOMS

IBM has confirmed that when an IBM AS/400 is used as a file server, Windows will not recognize the AS/400 folders when Windows or Windows for Workgroups is running in 386 enhanced mode. However, Windows 3.1 or 3.11 will recognize these folders when running in standard mode.

CAUSE

According to IBM, the problem is due to the AS/400 device drive ECYDDX.SYS, which allocates logical drives.

NOTE: This device driver may prevent Windows for Workgroups 3.11 File Manager from recognizing drive A or B, resulting in the
drive A: or B: does not exist
error message.

MORE INFORMATION

To correct the problem, obtain a Program Temporary Fix (PTF) for the appropriate version, release, and modification level of ECYDDX.SYS. This information can be obtained by typing go licpgm and choosing Option 10 on the AS/400.

To update the system, obtain one of the following files

  • For V2R1M0 use (PTF) SF10163
  • For V2R1M1 use (PTF) SF10165
  • For Extended DOS use (PTF) SF09768
where V is the version, R is the revision, and M is the modification level.

These corrections may be obtained from IBM by using the ECS Modem connected to the AS/400. Please contact IBM if you have further questions regarding this particular problem or how to correct it.

The AS/400 included here is manufactured by a vendor independent of Microsoft; we make no warranty, implied or otherwise, regarding this product's performance or reliability.

Modification Type:MajorLast Reviewed:11/25/2003
Keywords:KB87977