Windows Err Msg: Micro Channel Bus Time-out Error (87276)
The information in this article applies to:
- Microsoft Windows 3.1
- Microsoft Windows 3.11
This article was previously published under Q87276 SYMPTOMS
When you are using the Micro Channel (MC) version of the Creative Labs
Sound Blaster with Windows 3.1, you receive the following error message:
System error: Micro Channel bus time-out error detected.
System halted.
CAUSE
This message is caused by an MC device and the MC bus not synching
properly during the bus arbitration process. This error may be caused
by the Sound Blaster MCA or a third-party floppy disk drive for PS/2s.
WORKAROUND
Run Windows in standard mode instead of 386 enhanced mode. This error
can also occur in standard mode, but it is less likely.
NOTE: You should not use the MCADMA= switch (in the SYSTEM.INI file
[386Enh] section) on any PS/2 other than the model 55sx. This switch
should not be used for this problem.
STATUS
Creative Labs is researching this problem and we will post new information
here in the Microsoft Knowledge Base as it becomes available.
Modification Type: | Major | Last Reviewed: | 10/12/2003 |
---|
Keywords: | KB87276 |
---|
|