MS-DOS Err Msg: Not Ready Reading Drive A (85685)
The information in this article applies to:
This article was previously published under Q85685 SYMPTOMS
If you use Sysgen's Omnibridge controller card driver ONMIBRG.SYS version
3.3 or earlier with Windows version 3.1, the following MS-DOS error message
is displayed after you type win to execute
Windows:
Not ready reading drive A
Abort, Retry, Fail
Same problem was reported with Sysgen driver named BRIDGE_B.DRV
CAUSERESOLUTION
You can either updated the driver to version 3.5 or later (updates
are available from Sysgen), or you can follow this procedure:
- Insert a disk in drive A.
- Retry several times.
- Remark out the OMNIBRG.SYS driver.
MORE INFORMATION
The Sysgen Omnibridge is a floppy drive controller card that allows
high-density floppy support on XTs and above for up to four floppy
drives. It can be the primary or secondary controller.
The Sysgen products included here are manufactured by vendors
independent of Microsoft; we make no warranty, implied or otherwise,
regarding these products' performance or reliability.
KBCategory: kbhw kberrmsg kb3rdparty
KBSubcategory: win31 winboot
Modification Type: | Major | Last Reviewed: | 10/5/1999 |
---|
Keywords: | KB85685 |
---|
|