No MS-DOS Prompt on Novell Network with Windows 3.1 (83719)
The information in this article applies to:
- Microsoft Windows 3.1
- Microsoft Windows 3.11
This article was previously published under Q83719 SUMMARY
If you are running Windows version 3.1 on a Novell network and cannot
run MS-DOS Prompt, the Windows 3.1 VPICD driver may not be loaded.
When you attempt to run MS-DOS Prompt, it either will not run or you
will receive the following error message:
INVALID VxD DYNAMIC LINK CALL TO # 0003, SERVICE 0013
To correct this problem, edit the [386 Enh] section of the SYSTEM.INI
file. Change the line that reads DEVICE=VPICDA.386, to DEVICE=*VPICD.
This loads the latest VPICD driver that ships with Windows 3.1.