Time stamps may not be synchronized correctly on a large Symmetric Multiprocessing computer that is running Windows Server 2003 (827909)



The information in this article applies to:

  • Microsoft Windows Server 2003, 64-Bit Datacenter Edition
  • Microsoft Windows Server 2003, 64-Bit Enterprise Edition

SYMPTOMS

Time stamps may not be synchronized correctly on a large Symmetric Multiprocessing (SMP) computer that is running Microsoft Windows Server 2003.

CAUSE

This problem may occur if a program queries a Time Stamp Counter (TSC) in one processor for a time stamp, and the Task Scheduler service moves the program to another processor. When the program queries another processor's TSC, the time stamp information is not synchronized with the previous query to the other processor.

RESOLUTION

Hotfix information

A supported hotfix is now available from Microsoft, but it is only intended to correct the problem that is described in this article. Only apply it to systems that are experiencing this specific problem. This hotfix may receive additional testing. Therefore, if you are not severely affected by this problem, we recommend that you wait for the next Windows Server 2003 service pack that contains this hotfix.

To resolve this problem immediately, contact Microsoft Product Support Services to obtain the hotfix. For a complete list of Microsoft Product Support Services telephone numbers and information about support costs, visit the following Microsoft Web site:Note In special cases, charges that are ordinarily incurred for support calls may be canceled if a Microsoft Support Professional determines that a specific update will resolve your problem. The usual support costs will apply to additional support questions and issues that do not qualify for the specific update in question.

Prerequisites

No prerequisites are required.

Restart requirement

You must restart your computer after you apply this hotfix.

Hotfix replacement information

This hotfix does not replace any other hotfixes.

File information

The English version of this hotfix has the file attributes (or later) that are listed in the following table. The dates and times for these files are listed in coordinated universal time (UTC). When you view the file information, it is converted to local time. To find the difference between UTC and local time, use the Time Zone tab in the Date and Time tool in Control Panel.
   Date         Time   Version            Size    File name        Platform
   ------------------------------------------------------------------------
   14-Nov-2003  19:16  5.2.3790.103      305,664  Hal.dll          IA-64

STATUS

Microsoft has confirmed that this is a problem in the Microsoft products that are listed in the "Applies to" section of this article.