SYMPTOMSAfter you configure the energy-saving settings for a liquid
crystal display (LCD) monitor by using the following steps, some portable
computers that are running Windows XP SP1 may enter a state where the monitor
does not turn on again, even though you press a key on the keyboard.
- In Control Panel, double-click Power
Options. The Power Options Properties dialog box
appears.
- Under Plugged in, set Turn off
monitor to After 1 min.
- Wait for the monitor to turn off after 1 minute.
- Close the lid of the portable computer.
- Disconnect the computer from the power source.
- Open the lid of the portable computer.
The monitor
may not come on, even after you press a key on the keyboard.
. CAUSEThis error results from a process timing issue for the LCD
Power revert in Windows XP SP1.RESOLUTIONTo resolve this issue, create the following registry key: HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\GraphicsDrivers LidCloseSetPower WARNING: If you use Registry Editor incorrectly, you may cause serious
problems that may require you to reinstall your operating system. Microsoft
cannot guarantee that you can solve problems that result from using Registry
Editor incorrectly. Use Registry Editor at your own risk.
STATUS Microsoft
has confirmed that this is a problem in the Microsoft products that are listed
at the beginning of this article.
Modification Type: | Major | Last Reviewed: | 5/19/2005 |
---|