SYMPTOMS
In Coordinated Universal Time (Greenwich Mean Time)+
X hours time zones, Microsoft BizTalk Server 2004 rejects BizTalk Framework (BTF) receipts that are generated by a BizTalk Server 2004 computer. You receive the following error message in the event view:
There was a failure executing the receive pipeline: "BTF.BTFReceiptReceivePipeline" Source: "BizTalk Framework disassembler" Receive Location: "C:\BTFSample\receiptin\*.xml" Reason: A BizTalk Framework document was received with an expired "6/8/2004 11:06:47 AM" timestamp. This message will be suspended.
RESOLUTION
Service pack information
To resolve this problem, obtain the latest service pack for Microsoft BizTalk Server 2004. For more information, click the following article number to view the article in the Microsoft Knowledge Base:
888751 How to obtain the latest BizTalk Server 2004 service pack
Hotfix information
Prerequisites
No prerequisites are required.
Restart requirement
You do not have to restart your computer after you apply this hotfix.
Hotfix replacement information
This hotfix does not replace any other hotfixes.
File information
The English version of this hotfix has the file attributes (or later) that are listed in the following table. The dates and times for these files are listed in coordinated universal time (UTC). When you view the file information, it is converted to local time. To find the difference between UTC and local time, use the
Time Zone tab in the Date and Time tool in Control Panel.
Date Time Version Size File name
----------------------------------------------------------------------------------
16-Jun-2004 00:27 3.0.5313.0 266,240 Microsoft.biztalk.pipeline.components.dll
Note Because of file dependencies, the most recent hotfix that contains these files may also contain additional files.