Error Message When Installing Roland MIDI Devices (82417)



The information in this article applies to:

  • Microsoft Windows 3.1
  • Microsoft Windows 3.11

This article was previously published under Q82417

SYMPTOMS

When you install either the Roland LAPC1 or Roland MPU-401 driver from the Microsoft Windows Control Panel, the following message is generated:
Roland MPU-401

A configuration problem has occurred. Use the drivers option in the Control Panel to reconfigure the MPU-401 driver.

CAUSE

This error message occurs because the current settings for the Roland device are incorrect (you haven't had a chance to set them yet).

This message only appears when either the PORT or IRQ for the Roland device is incorrect. After correctly setting them, you will no longer see the message.

RESOLUTION

Ignore this message during first installation and choose the OK button to correctly set the PORT and IRQ settings for the device.

MORE INFORMATION

There are separate entries for the Roland MPU-401 and the Roland LAPC1 in the dialog box that appears when you select the Drivers icon from the Control Panel, but they actually use the same Windows device driver.

The Roland LAPC1 is comprised of a Roland MPU-401 and a Roland MT-32. Access to the LAPC1 is provided using the MPU-401. When installing the Windows driver for the LAPC1, the error message is the same as for the MPU-401 because this message comes from the Windows device driver MPU401.DRV.

The Roland MPU-401 is a port; it provides similar services as a serial port.

KBCategory: kbmm kb3rdparty
KBSubcategory: win31 windrvr

Modification Type:MajorLast Reviewed:10/13/2003
Keywords:KB82417