The following is the contents of the Microsoft Mail version 2.1e modem script file USRHST.MDM, which can be compiled with SCRCOMP.EXE:
;*********************************************************************
;
;                    Microsoft Mail Script File
;
;       Filename: usrhst.mdm
;       Date    : Oct 26, 1990
;       Script  : Script file for USRobotics Courier HST modems
;
;     This modem has a bank of DIP-Switches on the back. These should
;  be set as follows (note that switches 1 and 6 differ from factory
;  settings):
;
;                     QUAD  1  2  3  4  5  6  7  8  9  10
;                ON   XXXX  X              X  X        X
;                OFF           X  X  X  X        X  X
;
;
;     This script file contains the standard modem setup strings used
;  by the External, Transmit and Listen programs. There are five
;  procedures defined in this script file for setting up the modem and
;  for connecting to a remote External machine.
;
;     The modem setup strings used here will be adequate for most
;  people but there may be some changes required if you are dialing
;  overseas and require a longer wait for Carrier Detect (S7 register)
;  or if you wish to change the speaker volume. Note that if you used
;  the -Innn option in version 1.0 or 2.0 that you will have to modify
;  the S7 register and recompile this script file.
;
;     Consult your modem manual for more information on setup options.
;
;  Script procedures defined:
;       INITIALIZE
;       RESET
;       CALL
;       ANSWER
;       DISCONNECT
;
;  Return codes for External, Transmit, Listen:
;       0  - OK
;       1  - CONNECT 300
;       2  - not defined
;       3  - NO CARRIER
;       4  - ERROR
;       5  - CONNECT 1200
;       6  - not defined
;       7  - BUSY
;       8  - NO ANSWER
;       9  - not defined
;      10  - CONNECT 2400
;      11  - not defined
;      12  - CONNECT 9600 (high speed connection)
;
;
;*********************************************************************


INITIALIZE:
        title "USRobotics HST/V.32 Script"

        baud 19200              ; set the baud rate
        display "   Baud Rate : 19200"
        $attempts = 5

init_retry:
        sendln "ATZ"           ; reset modem to default settings
        wait 2
        waitrsp 1

        if ("0" isin response)
            goto reset_okay

        if ("OK" isin response)
            {
reset_okay:
            sendln "AT&F&B1&H1&R2&S1E0M1V0X3"
            wait 2
            waitrsp 3

            if ("0^M" isin response)
                {
                sendln "ATS0=0S10=50&W"
                waitrsp 3
                if (response = "0^M")
                    return 0
                }
             }
        dec $attempts
        if ($attempts > 0)
                goto init_retry

        return 4


RESET:
        baud 19200              ; set the baud rate
        display "   Baud Rate : 19200"

        sendln "ATZ"           ; reset modem to default settings
        waitrsp 2

        if (response = "0^M")
             return 0
        else
             return 4


CALL:
        $ret = 8               ; set default ret code to "no answer"

        clearrsp               ; clear the response buffer

        echo 0                 ; do not display phone number

        sendln "ATD" + dial_mode + phone_number  ; execute the dial up

        echo 1                 ; turn echo back on

        waitrsp 120            ; wait until the modem responds (max
                               ;    2 minutes)

        if (response = "1^M")
          {
          display ">>> CONNECT 300 <<<"
          $ret = 1
          }
        else if (response = "3^M")
          {
          display ">>> NO CARRIER <<<"
          $ret = 8             ; no answer or no connect
          }
        else if (response = "5^M")
          {
          display ">>> CONNECT 1200 <<<"
          $ret = 5
          }
        else if (response = "7^M")
          {
          display ">>> BUSY <<<"
          $ret = 7             ; busy
          }
        else if (response = "10^M")
          {
          display ">>> CONNECT 2400 <<<"
          $ret = 10
          }
        else if (response = "13^M")
          {
          display ">>> CONNECT 9600 <<<"
          $ret = 12
          }
        else if (response = "18^M")
          {
          display ">>> CONNECT 4800 <<<"
          $ret = 11
          }
        else if (response = "14^M")
          {
          display ">>> CONNECT 300/ARQ <<<"
          $ret = 1
          }
        else if (response = "15^M")
          {
          display ">>> CONNECT 1200/ARQ <<<"
          $ret = 5
          }
        else if (response = "16^M")
          {
          display ">>> CONNECT 2400/ARQ <<<"
          $ret = 10
          }
        else if (response = "17^M")
          {
          display ">>> CONNECT 9600/ARQ <<<"
          $ret = 12
          }
        else if (response = "19^M")
          {
          display ">>> CONNECT 4800/ARQ <<<"
          $ret = 11
          }

        return $ret            ; return connect baud rate to
                               ;    application


ANSWER:
        $ret = 8               ; set default ret code to "no answer"

        waitrsp 1              ; see if phone is ringing

        if (response = "2^M")  ; 2 is numeric form of "RING"
            {
            if (listen = 1)    ; see if Listen program is running or
                sendln "ATD"   ; not answer phone in originate mode
                               ;    (Listen)
            else
                sendln "ATA"   ; answer the phone normally

            waitrsp 120        ; wait for return code from modem (max
                               ;    2 minutes)


            if (response = "1^M")
              {
              display ">>> CONNECT 300 <<<"
              $ret = 1
              }
            else if (response = "3^M")
              {
              display ">>> NO CARRIER <<<"
              $ret = 8             ; no answer or no connect
              }
            else if (response = "5^M")
              {
              display ">>> CONNECT 1200 <<<"
              $ret = 5
              }
            else if (response = "10^M")
              {
              display ">>> CONNECT 2400 <<<"
              $ret = 10
              }
            else if (response = "13^M")
              {
              display ">>> CONNECT 9600 <<<"
              $ret = 12
              }
            else if (response = "18^M")
              {
              display ">>> CONNECT 4800 <<<"
              $ret = 11
              }
            else if (response = "14^M")
              {
              display ">>> CONNECT 300/ARQ <<<"
              $ret = 1
              }
            else if (response = "15^M")
              {
              display ">>> CONNECT 1200/ARQ <<<"
              $ret = 5
              }
            else if (response = "16^M")
              {
              display ">>> CONNECT 2400/ARQ <<<"
              $ret = 10
              }
            else if (response = "17^M")
              {
              display ">>> CONNECT 9600/ARQ <<<"
              $ret = 12
              }
            else if (response = "19^M")
              {
              display ">>> CONNECT 4800/ARQ <<<"
              $ret = 11
              }

            }

        return $ret            ; return connect baud rate to
                               ;    application


DISCONNECT:
        wait 2                 ; wait 2 seconds

        send "+++"             ; send escape sequence to put modem
                               ;    back to command state
        wait 2                 ; wait 2 seconds

        clearrsp               ; clear the response buffer

        sendln "ATH0"          ; hang up the phone

        waitrsp 3              ; wait for a response

        if (response != "0^M") ; if hang up failed, drop DTR to force
                               ;    hang up
            {
            DTR 0              ; drop DTR to reset modem
            wait 2             ; some modems require a delay here
            DTR 1              ; raise DTR
            clearrsp           ; clear response buffer
            }

        return 0               ; always return OK
				

Modification Type:MajorLast Reviewed:11/4/1999