Oracle Requires Windows 3.0a to Run in Standard Mode (69830)
The information in this article applies to:
- Microsoft Windows 3.0
- Microsoft Windows 3.0a
This article was previously published under Q69830 SYMPTOMS
The MS-DOS-based version of Oracle (a relational database) system stops
responding (hangs) if it is run under Window version 3.0 in standard mode.
RESOLUTION
Oracle requires Microsoft Windows version 3.0a or later to run correctly
under standard mode Windows. Windows 3.0a contains a correction to the
MS-DOS protected-mode interface (DPMI) that Windows uses for memory
management. Changes made to the Windows 3.0a MS-DOS extender (DOSX.EXE)
have now made DPMI (interrupt 31h) translation services reentrant. This
change allows Oracle to run correctly in standard mode.
MORE INFORMATION
Oracle running under standard-mode Windows can access both local and
remote databases. You can only access the remote databases (NOT the local
databases) when running in enhanced mode. Oracle products do not run in
real mode.
The Oracle product included here is manufactured by a vendor independent
of Microsoft. We make no warranty, implied or otherwise, regarding this
product's performance or reliability.
Modification Type: | Minor | Last Reviewed: | 7/7/2005 |
---|
Keywords: | KB69830 |
---|
|