Using HIMEM.SYS with AT&T 6300 and AT&T 6300 Plus (64880)



The information in this article applies to:

  • Microsoft Windows 3.0
  • Microsoft Windows 3.0a
  • Microsoft Windows 3.1
  • Microsoft Windows 3.11

This article was previously published under Q64880

SUMMARY

The HIMEM.SYS file does not work on an AT&T 6300 because the AT&T 6300 uses an 8086 processor and only an 80286 or greater processor can access extended memory.

HIMEM.SYS is an extended memory manager that allows Microsoft Windows to access the extended memory on your 80286, 80386, or 80486 computer.

MORE INFORMATION

HIMEM.SYS works on an AT&T 6300 PLUS. However, you must use the "/M:att6300plus" or "/M:5" switch to access extended memory on this machine. For example, your CONFIG.SYS file should contain the following line:
   DEVICE=C:\HIMEM.SYS /M:5
				

-or-

   DEVICE=C:\HIMEM.SYS /M:AT&T6300PLUS
				
If you are using the AT&T 6300 PLUS with an Intel Above Board, you may have to make modifications to use the RAMDRIVE.SYS file. If you experience a problem, contact AT&T.

AT&T suggests using BIOS version 1.43 or later with the AT&T 6300. You can obtain a more recent version of the ROM BIOS from the AT&T National Parts Center.

The AT&T products included here are manufactured by a vendor independent of Microsoft; we make no warranty, implied or otherwise, regarding these products' performance or reliability.

Modification Type:MinorLast Reviewed:7/7/2005
Keywords:KB64880