Using the QMS Jetscript with Windows 3.0 (64861)
The information in this article applies to:
- Microsoft Windows 3.0
- Microsoft Windows 3.0a
This article was previously published under Q64861 SUMMARY
The QMS Jetscript may not function correctly under Microsoft Windows
version 3.0 unless a file is created and copied to the printer. To
create this file, do the following:
- Using a text editor such as Notepad, type the following text
(all characters must be lowercase):
serverdict begin 0 exitserver
statusdict begin
0 setdefaultparallel
0 setparallel
start - Save this file as R.ON for Reverse channel ON (the file must be
saved as an unformatted text file or ASCII file).
- Copy R.ON to the printer. You can do this by entering the
following from a DOS prompt
where x is a number between 1 and 3
MORE INFORMATION
The information in this article was taken from the QMS technical notes. Any
questions concerning this procedure should be directed to QMS.
The QMS product included here is manufactured by a vendor independent of
Microsoft; we make no warranty, implied or otherwise, regarding this
product's performance or reliability.
Modification Type: | Minor | Last Reviewed: | 7/7/2005 |
---|
Keywords: | KB64861 |
---|
|