Cannot Close Files After UPS Service Warning Message (64487)






This article was previously published under Q64487

SYMPTOMS

After a power failure occurs on an uninterruptible power supply (UPS) protected server, this message appears at the workstation:
A power failure has occurred at \\SERVER1. Please terminate all activity with this server.
Attempting to save open files fails and an error message appears, indicating that the path is no longer available.

CAUSE

The power failure message is sent to all session connected workstations, MESSDELAY seconds after power is lost. Then, unless the UPS has the capability to inform the server of a low-power state (see note below), the UPS server stops the SERVER service BATTERYTIME seconds after the point of initial power loss.

MESSDELAY defaults to 5 seconds and BATTERYTIME defaults to 60 seconds. Thus, by default, all files must be closed within 55 seconds of receiving the warning message. If the files are not closed within (BATTERYTIME minus MESSDELAY) seconds from the initial power failure warning, you then cannot close the files because the server service has stopped.

RESOLUTION

When the server service is properly stopped, as it is when it is stopped by the UPS service, all open files are safely closed in the state they were in when they were last saved.

Using a NET USE command at the workstation shows that connections to the stopped server are in a "disconnected" state. After power returns and the server service is restarted, workstation application files can be closed safely.

MORE INFORMATION

  1. At a network workstation, a Microsoft Word document is opened from a remote share-point linked to drive F.
  2. Power is lost at the server. All open files are closed and the server service is stopped before the user has a chance to save the Word document.
  3. The user tries to save the Word document and receives a "disk error" message notification. Drive F is now in a "disconnected" state.
  4. Power is restored to the server and the server service is restarted; shares are re-established.
  5. The user tries again to save the Word document (as described in step 3 above). Drive F is automatically reconnected and the Word document is saved successfully.
Note: If the UPS has the capability to inform the UPS service of a "low battery" state, and the SIGNALS' second digit is accordingly set to 1, the UPS service ignores BATTERYTIME and does not initiate server shutdown until it receives the low-power signal from the UPS.

Modification Type: Major Last Reviewed: 11/21/2002
Keywords: kbnetwork KB64487