FIX: Incorrect 1394 Node Becomes Cycle Master (326464)
The information in this article applies to:
- Microsoft Windows XP Professional
This article was previously published under Q326464 SYMPTOMS
After you start your computer, although some conferencing cameras enumerate correctly and appear in Device Manager with no errors, they do not stream video.
CAUSE
With certain 1394 topologies at startup time, the 1394 host controller driver (1394Bus.sys/OHCI1394.sys) incorrectly chooses the wrong 1394 node as the Cycle Master. This results in no start cycle packets and, therefore, no isochronous streaming.
WORKAROUND
To work around this problem so that the camera correctly streams video, follow these steps:
- Unplug the conferencing camera.
- Plug the camera in again.
- Restart the program; this causes a bus reset and solves the problem.
RESOLUTION
The English version of this fix has the file attributes (or later) that are listed in the following table. The dates and times for these files are listed in coordinated universal time (UTC). When you view the file information, it is converted to local time. To find the difference between UTC and local time, use the Time Zone tab in the Date and Time tool in Control Panel.
Date Time Version Size File name Operating system
-------------------------------------------------------------------------
15-AUG-2002 09:31 5.1.2600.54 49,792 1394BUS.SYS Windows XP
STATUSMicrosoft has confirmed that this is a bug in the Microsoft products that are listed at the beginning of this article.
Modification Type: | Minor | Last Reviewed: | 9/27/2005 |
---|
Keywords: | kbHotfixServer kbQFE kbbug kbfix kbOSWin2000fix kbWinXPsp1fix KB326464 |
---|
|