BUG: Issues Related to Using ODBC Driver for DB2 with File DSNs (323803)
The information in this article applies to:
- Microsoft Host Integration Server 2000
This article was previously published under Q323803 SYMPTOMS
The following issues have been identified when using the Microsoft ODBC
Driver for DB2 with file data source names (DSNs):
- An ODBC file DSN that is configured to use the Microsoft ODBC
Driver for DB2 does not retain the DSN that is specified when the DSN
is created. The Data Source Name value is blank when you use the
ODBC Data Source Administrator to configure the file DSN.
- The Connect button that is available in the ODBC
Driver for DB2 Authentication dialog box when you configure the
file DSN does not try to make an ODBC connection to the target database
that is specified in the DSN.
CAUSE- The ODBC Driver for DB2 does not correctly parse the file DSN
path, which results in the failure to retain the Data Source
Name.
- The ODBC Driver for DB2 was not designed to try to make an
ODBC connection when you click Connect.
RESOLUTIONTo resolve this problem, obtain the latest service pack for Host Integration Server 2000. For additional information, click the following article number to view the article in the
Microsoft Knowledge Base:
328152 How to Obtain the Latest Host Integration Server 2000 Service Pack
STATUSMicrosoft has confirmed that this is a problem in Microsoft Host Integration Server 2000. This problem was first corrected in Host Integration Server 2000 Service Pack 1.
Modification Type: | Minor | Last Reviewed: | 3/11/2005 |
---|
Keywords: | kbBug kbfix kbHostIntegServ2000preSP1fix kbHostIntegServ2000SP1fix KB323803 |
---|
|