PRB: XLANG Schedules Fail After Failover When You View COM+ Application Properties (323572)
The information in this article applies to:
- Microsoft BizTalk Server 2000
- Microsoft BizTalk Server 2000 SP1a
- Microsoft BizTalk Server 2000 SP2
- Microsoft BizTalk Server 2002
This article was previously published under Q323572 SYMPTOMS
When you view the properties of any COM+ application from the Component Services Microsoft Management Console (MMC) on the inactive node of a BizTalk cluster, the XLANG schedules may fail after failover. This is specific only to any COM+ application that has an activation type of server application.
CAUSE
When you view COM+ application properties on any COM+ server application, a copy of the XLANG scheduler engine starts. When this occurs, BizTalk Server failover does not behave as expected because an instance of the XLANG scheduler is running.
RESOLUTION
Make sure to shut down the copy of the XLANG Scheduler engine that is started by the component service when you finish viewing the COM+ application properties on the inactive node. When you view the properties in this scenario, follow these steps:
- View the properties on the COM+ server application.
- Click to select the XLANG scheduler COM+ application in the Component Service MMC.
- Right-click the XLANG scheduler COM+ application, and then click Shut Down.
- Close the Component Services MMC.