HIS2000: Data Queue ActiveX Control Stops Responding When Connection Is Lost (320547)



The information in this article applies to:

  • Microsoft Host Integration Server 2000

This article was previously published under Q320547

SYMPTOMS

If the link to an AS/400 system is lost, or some other type of networking failure occurs, a program that uses the Microsoft Data Queue ActiveX Control may stop responding (hang).

CAUSE

If any errors occur while you are receiving a reply, the request- completion event is not signaled.

RESOLUTION

To resolve this problem, obtain the latest service pack for Host Integration Server 2000. For additional information, click the following article number to view the article in the Microsoft Knowledge Base:

328152 How to Obtain the Latest Host Integration Server 2000 Service Pack

The English-language version of this fix should have the following file attributes or later.
File nameDateTime
MSEIGDQ.dll03/29/0213:51

NOTE: Because of file dependencies, the most recent fix that contains the preceding files may also contain additional files.

STATUS

Microsoft has confirmed that this is a problem in the Microsoft products that are listed at the beginning of this article. This problem was first corrected in Host Integration Server 2000 Service Pack 1.

Modification Type:MinorLast Reviewed:4/7/2005