SYMPTOMS
If you have the /3GB boot switch enabled, the ASP.NET
worker process (Aspnet_wp.exe) does not start. If you request an ASP.NET page, you receive one of the following error messages in the browser:
HTTP 500 - Internal server error
-or-
A dynamic link library (DLL) initialization routine
failed
RESOLUTION
To resolve this problem, obtain the latest service pack for the Microsoft .NET Framework. For additional information, click the following article number to view the article in the Microsoft Knowledge Base:
318836 INFO: How to Obtain the Latest
.NET Framework Service Pack
The English version of this hotfix has the file attributes (or later) that are listed in the following table. The dates and times for these files are listed in coordinated universal time (UTC). When you view the file information, it is converted to local time. To find the difference between UTC and local time, use the
Time Zone tab in the Date and Time tool in Control Panel.
Date Time Version Size File name
--------------------------------------------------------------
21-Apr-2002 12:15 1.0.3705.258 192,512 Aspnet_isapi.dll
21-Apr-2002 12:10 19,332 Aspnet_perf.ini
21-Apr-2002 12:15 1.0.3705.258 24,576 Aspnet_regiis.exe
21-Apr-2002 12:15 1.0.3705.258 28,672 Aspnet_wp.exe
05-Apr-2002 12:07 8,709 Smartnav.js
05-Apr-2002 12:07 7,003 Smartnavie5.js
22-Apr-2002 00:39 1.0.3705.258 1,183,744 System_web.dll
NOTE: After applying the fix, add an environment variable named
ASPNETENABLE3GB and set the value to
1 to start the ASP.NET worker process. Otherwise, the problem that
is mentioned in the "Symptoms" section still occurs. Although the ASP.NET
Worker Process will now run on a computer with the 3GB switch enabled, ASP.NET
does not utilize the extra memory.