Switch Settings For Pure Data ARCNET Adapters (32849)



The information in this article applies to:

  • Microsoft Windows 1.1
  • Microsoft Windows 2.03
  • Microsoft Windows 2.1
  • Microsoft Windows 2.11
  • Microsoft Windows 3.0
  • Microsoft Windows 3.0a
  • Microsoft Windows 3.1
  • Microsoft Windows 3.11

This article was previously published under Q32849

SUMMARY

This article discusses switch settings for the IBM Pure Data ARCNET Network Adapter.

MORE INFORMATION

The following are switch-configurable parameters for the Pure Data ARCNET adapter and the conflicts that may result:
  1. The Interrupt Line address may conflict with devices such as the Microsoft Bus Mouse, hard drive controllers, serial and parallel ports.
  2. The Base I/O address may conflict with expanded memory boards.
  3. The Memory Map Address may conflict with the memory addresses used by expanded memory board drivers, 3270 cards, ESDI hard drive controllers, and display adapters.
You may have to change switch settings on the Pure Data ARCNET Adapter and/or other cards in the system to avoid such conflicts.

The following are Interrupt Line Address switch settings:
   (Switch SW2)
      Interrupt 2 - Switch 3 off, 4 through 8 on
      Interrupt 3 - Switch 3 on, 4 off, 5 through 8 on
      Interrupt 4 - Switches 3 & 4 on, 5 off, 6 through 8 on
      Interrupt 5 - Switches 3 through 5 on, 6 off, 7 & 8 on
      Interrupt 7 - Switches 3 through 7 on, 8 off
				
The following are Base I/O Address switch settings:
   (Switches SW1 and SW2)
      Address 2E0h - SW1 7 & 8 on, SW2 1 on, 2 off
      Address 2F0h - SW1 7 & 8 on, SW2 1 & 2 on
				
The following are Memory Address switch settings:
   (Switch SW1)
      Address C000 - Switches 1 & 2 on, 3 & 4 off
      Address D000 - Switches 1 & 2 on, 3 off, 4 on
      Address E000 - Switches 1, 2 & 3 on, 4 off
				

Modification Type:MinorLast Reviewed:7/7/2005
Keywords:KB32849