FIX: BizTalk X12 Parser Fails When the Trigger Segment Is Missing (318369)



The information in this article applies to:

  • Microsoft BizTalk Server 2000
  • Microsoft BizTalk Server 2000 SP1
  • Microsoft BizTalk Server 2000 SP1a
  • Microsoft BizTalk Server 2002

This article was previously published under Q318369

SYMPTOMS

The BizTalk X12 parser may fail when the trigger segment of a triggered loop is missing and another segment is found in that loop.

CAUSE

This behavior can occur when you parse an X12 4010 schema.

RESOLUTION

To resolve this problem, obtain the latest service pack for BizTalk Accelerator for HIPAA 1.0. For additional information, click the following article number to view the article in the Microsoft Knowledge Base:

321233 How to Obtain the latest BizTalk Accelerator for HIPAA 1.0 Service Pack

The English-language version of this fix should have the following file attributes or later:
   Date         Time   Version      Size    File name
   --------------------------------------------------
   02/20/2002   02:58p 2.1.1910.0   278,800 CISHipaaParser.dll
   02/20/2002   02:58p 2.1.1910.0   483,600 HipaaValidateDoc.dll
				

STATUS

Microsoft has confirmed that this is a problem in the Microsoft products that are listed at the beginning of this article. This problem was first corrected in BizTalk Accelerator for HIPAA 1.0 Service Pack 1a.

Modification Type:MinorLast Reviewed:9/27/2005
Keywords:kbHotfixServer kbQFE kbbug kbfix KB318369