A National Semiconductor IDE Controller May Not Function Correctly (312190)



The information in this article applies to:

  • Microsoft Windows 2000 Server SP1
  • Microsoft Windows 2000 Server SP2
  • Microsoft Windows 2000 Advanced Server SP1
  • Microsoft Windows 2000 Advanced Server SP2
  • Microsoft Windows 2000 Professional SP1
  • Microsoft Windows 2000 Professional SP2

This article was previously published under Q312190
IMPORTANT: This article contains information about modifying the registry. Before you modify the registry, make sure to back it up and make sure that you understand how to restore the registry if a problem occurs. For information about how to back up, restore, and edit the registry, click the following article number to view the article in the Microsoft Knowledge Base:

256986 Description of the Microsoft Windows Registry

SYMPTOMS

In some cases, some National Semiconductor IDE controllers may be interpreted by Windows 2000 as not supporting Direct Memory Access (DMA) and use Processor Input/Output (PIO) mode instead.

RESOLUTION

To resolve this problem, obtain the latest service pack for Windows 2000. For additional information, click the following article number to view the article in the Microsoft Knowledge Base:

260910 How to Obtain the Latest Windows 2000 Service Pack

The English version of this fix should have the following file attributes or later:
   Date         Time   Version      Size    File name
   ----------------------------------------------------
   19-Nov-2001  13:24  5.0.2195.46  22,032  Pciidex.sys

				

STATUS

Microsoft has confirmed that this is a problem in the Microsoft products that are listed at the beginning of this article. This problem was first corrected in Windows 2000 Service Pack 3.

MORE INFORMATION

WARNING: If you use Registry Editor incorrectly, you may cause serious problems that may require you to reinstall your operating system. Microsoft cannot guarantee that you can solve problems that result from using Registry Editor incorrectly. Use Registry Editor at your own risk.

After you install the hotfix, you must make a registry change to enable the hotfix:
  1. Start Registry Editor (Regedt32.exe).
  2. Locate and click the following key in the registry:

    HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Class\{4D36E96A-E325-11CE-BFC1-08002BE10318}\0000

  3. On the Edit menu, click Add Value, and then add the following registry value:

    Value name: IgnoreBusMasterStatusZeroBits
    Data type: REG_DWORD
    Radix: Decimal
    Value data: 1

  4. Quit Registry Editor.
For additional information about how to obtain a hotfix for Windows 2000 Datacenter Server, click the article number below to view the article in the Microsoft Knowledge Base:

265173 The Datacenter Program and Windows 2000 Datacenter Server Product

For additional information about how to install multiple hotfixes with only one reboot, click the article number below to view the article in the Microsoft Knowledge Base:

296861 Use QChain.exe to Install Multiple Hotfixes with One Reboot

For additional information about how to install Windows 2000 and Windows 2000 hotfixes at the same time, click the article number below to view the article in the Microsoft Knowledge Base:

249149 Installing Microsoft Windows 2000 and Windows 2000 Hotfixes


Modification Type:MinorLast Reviewed:9/26/2005
Keywords:kbHotfixServer kbQFE kbbug kbfix kbOSWin2000fix kbWin2000PreSP3Fix kbWin2000sp3fix KB312190