You Receive a Bugcheck in Usbhub.sys When You Remove or Add a USB Device (306453)
The information in this article applies to:
- Microsoft Windows 2000 Server SP1
- Microsoft Windows 2000 Server SP2
- Microsoft Windows 2000 Advanced Server SP1
- Microsoft Windows 2000 Advanced Server SP2
- Microsoft Windows 2000 Professional SP1
- Microsoft Windows 2000 Professional SP2
- Microsoft Windows 98 Second Edition
This article was previously published under Q306453 SYMPTOMS
When plug in or unplug a USB device, you may receive a bugcheck in the Usbhub.sys file, and you may receive the following stop code if your computer is not configured to automatically reboot:
STOP 0x0000000A (00000024, 00000002, 00000001, 8041f65e)
NOTE: These parameters may vary based on the system configuration.
RESOLUTIONTo resolve this problem, obtain the latest service pack for Windows 2000. For additional information, click the following article number to view the article in the
Microsoft Knowledge Base:
260910 How to Obtain the Latest Windows 2000 Service Pack
The English version of this fix for the Windows 2000 versions should have the following file attributes or later:
Date Time Version Size File name
-----------------------------------------------------
26-Sep-2001 14:19 5.0.2195.4413 40,112 Usbhub.sys
The English version of this fix for Windows 98 Second Edition should have the following file attributes or later:
Date Time Version Size File name
---------------------------------------------------
11-Jun-2002 08:56 4.10.0.2227 36,848 Usbhub.sys
STATUSMicrosoft has confirmed that this is a problem in the Microsoft products that are listed at the beginning of this article. This problem was first corrected in Windows 2000 Service Pack 3.
Modification Type: | Minor | Last Reviewed: | 9/26/2005 |
---|
Keywords: | kbHotfixServer kbQFE kbbug kbenv kberrmsg kbfix kbOSWin2000fix kbWin2000PreSP3Fix kbWin2000sp3fix KB306453 |
---|
|