FIX: Only First LOCAL Variable Generates CodeView Information (30416)
The information in this article applies to:
- Microsoft Macro Assembler (MASM) 5.1
This article was previously published under Q30416 SYMPTOMS
In the Microsoft Macro Assembler (MASM) version 5.1, only the first LOCAL
variable on a line generates CodeView information. Attempting to put a
watch on a LOCAL variable that is not the first LOCAL variable on a line
will cause Codeview to display the following message box:
--------------------------------
| ERROR |
| Unknown Symbol |
| Press Any Key to Continue... |
--------------------------------
RESOLUTION
To avoid the problem in MASM version 5.1, break up any lines that define
more than one LOCAL variable into multiple lines.
STATUS
Microsoft has confirmed this to be a problem in MASM version 5.1. This
problem was corrected in MASM version 5.1a.
Modification Type: | Minor | Last Reviewed: | 10/17/2003 |
---|
Keywords: | kbfix KB30416 |
---|
|