"WINNT32 /CHECKUPGRADEONLY /UNATTEND" Is Not Fully Automated (272308)



The information in this article applies to:

  • Microsoft Windows 2000 Server
  • Microsoft Windows 2000 Advanced Server
  • Microsoft Windows 2000 Professional

This article was previously published under Q272308

SYMPTOMS

If you use the /checkupgradeonly and /unattend:c:\unattend.txt parameters with Winnt32.exe and you use the following settings in the Unattended.txt file, users must click Finish to complete the process after the upgrade report is generated and saved:

[Unattended]
Win9xUpgrade=yes

[Win9xUpg]
ReportOnly=yes
SaveReportto=\\server\share\%computername%.txt

RESOLUTION

To resolve this problem, obtain the latest service pack for Windows 2000. For additional information, click the following article number to view the article in the Microsoft Knowledge Base:

260910 How to Obtain the Latest Windows 2000 Service Pack

The English version of this fix should have the following file attributes or later:
   Date      Time    Version        Size     File name
   ----------------------------------------------------
   09/12/00  04:58p  5.0.2196.2196  532,752  W95upg.dll
				

STATUS

Microsoft has confirmed that this is a problem in the Microsoft products that are listed at the beginning of this article. This problem was first corrected in Windows 2000 Service Pack 2.

MORE INFORMATION

For additional information about how to install Windows 2000 and Windows 2000 hotfixes at the same time, click the article number below to view the article in the Microsoft Knowledge Base:

249149 Installing Microsoft Windows 2000 and Windows 2000 Hotfixes


Modification Type:MinorLast Reviewed:9/23/2005
Keywords:kbHotfixServer kbQFE kbbug kbfix kbWin2000PreSP2Fix KB272308