Objects are removed when you convert partial replicas from Access 97 to Access 2000 (263171)
The information in this article applies to:
- Microsoft Access 2000
- Microsoft Access 97
This article was previously published under Q263171 Moderate: Requires basic macro, coding, and interoperability skills.
This article applies only to a Microsoft Access database (.mdb).
SYMPTOMS
You convert a Microsoft Access 97 partial replica to Access 2000. Then you synchronize the Access 97 partial replica with a converted full replica or with Design Master. All the database objects are removed from the converted partial replica except tables and queries.RESOLUTION
Create new partial replicas in Access 2000 from the converted Design Master.
STATUSMicrosoft has confirmed that this is a problem in the Microsoft products that are listed at the beginning of this article.
| Modification Type: | Major | Last Reviewed: | 11/19/2004 |
|---|
| Keywords: | kbbug kbnofix KB263171 |
|---|
|