Computer Does Not Restart During First Phase of RIS Installation (258093)
The information in this article applies to:
- Microsoft Windows 2000 Professional
This article was previously published under Q258093 SYMPTOMS
While you are performing a Remote Installation service (RIS) installation of Windows 2000 Professional on a computer that has an Intel Pro 100+ Management adapter, the computer pauses at the end of the first phase of Setup and displays the following message:
Restarting computer
The computer does not restart, but the installation proceeds if you restart the computer manually.
CAUSE
This problem can occur if the Intel Pro 100+ Management adapter has an older Pre-Boot Execution Environment (PXE) ROM.
RESOLUTION
Contact Intel for a updated (PXE) ROM for the Intel Pro 100+ Management adapter. There is an update for the Intel Pro 100+ Management adapter available at the following Intel Web site:
Microsoft provides third-party contact information to help you find technical support. This contact information may change without notice. Microsoft does not guarantee the accuracy of this third-party contact information. MORE INFORMATION
This issue has been reported on some models of Compaq computers that use the Intel Pro 100+ Management adapter, but may occur on other computers that use the same network adapter.
Modification Type: | Major | Last Reviewed: | 11/7/2003 |
---|
Keywords: | kbprb kbRemoteProg w2000ris KB258093 |
---|
|