This article was previously published under Q256281 SYMPTOMS
When you run the Site Builder Wizard, the following error message is displayed:
Generating Order Pipeline:
Writing File: plan.pcf
Commerce.PipeManager.1 error '80030005'
Access Denied.
/shop/manager/MSCS_CommerceSiteBuilderWizard/wz_pipeline_config.asp, line 770
The error message does not occur if you are authenticated as an Administrator on the Commerce Server computer.
CAUSE
This error message can occur due to insufficient file-level permissions in the \Winnt directory or its subdirectories.
RESOLUTION
Give the Everyone group Change permissions at the file level in the \Winnt directory on the Commerce Server computer.