XCON: Microsoft Exchange Connector for Novell GroupWise Does Not Process Non-Delivery Report for Message with Long Subject (249861)
The information in this article applies to:
- Microsoft Exchange Server 5.5
This article was previously published under Q249861 SYMPTOMS
The Microsoft Exchange Connector for Novell GroupWise may stop responding when it processes a non-delivery report (NDR) that contains a long subject line.
CAUSE
This issue can occur if there was a buffer overflow while the message was being processed, which caused the Exchange Connector for Novell GroupWise to stop responding.
RESOLUTIONTo resolve this problem, obtain the latest service pack for Exchange Server 5.5. For additional information, click the following article number to view the article in the
Microsoft Knowledge Base:
191014 XGEN: How to Obtain the latest Exchange Server 5.5 Service Pack
STATUSMicrosoft has confirmed that this is a problem in Microsoft Exchange Server version 5.5. This problem was first corrected in Exchange Server 5.5 Service Pack 4.
Modification Type: | Major | Last Reviewed: | 10/2/2003 |
---|
Keywords: | kbbug kbExchange550preSP4fix kbExchange550sp4Fix kbfix kbQFE KB249861 |
---|
|