IBM MQSeries TCP/IP Channels Do Not Start After Applying Service Pack 6 (249798)
The information in this article applies to:
- Microsoft Windows NT Server 4.0 SP6
- Microsoft Windows NT Workstation 4.0 SP6
This article was previously published under Q249798 SYMPTOMS
After you install Service Pack 6 (SP6) on Windows NT 4.0, IBM MQSeries TCP/IP-type channels no longer start. The following error message is listed in the Application log in Event Viewer:
Event ID: 9213
Source: MQSeries
Type: Error
Description:
A communications error for TCP/IP occurred.
An unexpected error occurred in communications.
The return code from the TCP/IP (setsockopt(SO_KEEPALIVE)) call was 10055 (X'2747'). Record these values and tell the systems administrator.
RESOLUTIONTo resolve this problem, obtain the latest service pack for Windows NT 4.0. For additional information, click the following article number to view the article in the
Microsoft Knowledge Base:
152734 How to Obtain the Latest Windows NT 4.0 Service Pack
This problem was first corrected in Windows NT 4.0 Service Pack 6a. STATUS
Microsoft has confirmed this to be a problem in Windows NT 4.0 Service Pack 6.
Modification Type: | Major | Last Reviewed: | 5/13/2003 |
---|
Keywords: | kbenv kberrmsg kbprb KB249798 |
---|
|