SMS: Data Loader Ignores Some Fields from an SMS 1.2 Client Hardware Inventory MIF (248227)
The information in this article applies to:
- Microsoft Systems Management Server 2.0
This article was previously published under Q248227 SYMPTOMS
When hardware inventory from a Microsoft Systems Management Server (SMS) version 1.2 client is passed from an SMS 1.2 child site to an SMS 2.0 parent site, the Last Login Name, Domain Name, and MAC Address fields in the Management Information Format (MIF) file are ignored by the SMS 2.0 Data Loader and are not written to the database as expected.
WORKAROUND
To work around this issue, use the SMS 1.2 site to query for Last Login Name, Domain Name, and MAC Addresses.
STATUSMicrosoft has confirmed that this is a problem in Systems Management Server version 2.0.
Modification Type: | Minor | Last Reviewed: | 6/14/2005 |
---|