Netlogon Event 3051, with Invalid Registry Entry in Event Viewer (245086)
The information in this article applies to:
- Microsoft Windows NT Server 4.0
- Microsoft Windows NT Workstation 4.0
This article was previously published under Q245086 SYMPTOMS
When you log on to a computer that is running Microsoft Windows NT Server 4.0 or Microsoft Windows NT Workstation 4.0, Event Viewer may record the following event:
Netlogon Event 3051, with an invalid registry entry.
CAUSE
This behavior can occur if the Scripts value in the registry is damaged.
RESOLUTIONIMPORTANT: This article contains information about modifying the registry. Before you
modify the registry, make sure to back it up and make sure that you understand how to restore
the registry if a problem occurs. For information about how to back up, restore, and edit the
registry, click the following article number to view the article in the Microsoft Knowledge Base:
256986 Description of the Microsoft Windows Registry
WARNING: If you use Registry Editor incorrectly, you may cause serious problems that may
require you to reinstall your operating system. Microsoft cannot guarantee that you can solve
problems that result from using Registry Editor incorrectly. Use Registry Editor at your own
risk.
To resolve this issue, delete and then re-create the Scripts registry value:
- Start Registry Editor (Regedt32.exe), and then locate the
following registry key:
HKEY_LOCAL_MACHINE\System\CurrentControlSet\Services\Netlogon\Parameters
- Locate and delete the Scripts value.
- Quit Registry Editor, and then restart the computer.
- Start Registry Editor, and then re-create the Scripts
value:
- Locate the following registry key:
HKEY_LOCAL_MACHINE\System\CurrentControlSet\Services\Netlogon\Parameters
- On the Edit menu, click Add Value.
- In the Value Name box, type
Scripts.
- In the Data Type box, click REG_EXPAND_SZ, and then
click OK.
- In the String box, type the following path, and then click
OK:
%SystemRoot%\System32\Repl\Import\Scripts NOTE: Make sure you type this path correctly. If the path is
incorrect, Event Viewer may report the following event after you
restart the computer:
Event 5706
Netlogon could not create share c:\winnt\system32\repl\import\scripts.
The Following error occurred: The System could not find the path specified.
- Quit Registry Editor, and then restart the computer.
Modification Type: | Major | Last Reviewed: | 8/27/2002 |
---|
Keywords: | kbprb KB245086 |
---|
|