XFOR: Host Messages Backed Up on OV/VM Connector (240439)
The information in this article applies to:
- Microsoft Exchange Server 5.5
This article was previously published under Q240439 SYMPTOMS
Messages on the host may be stuck in the Remote Spooling Communications Subsystem (RSCS) queue even though the Microsoft Exchange OfficeVision/VM (OV/VM) Connector is working properly. Stopping and then restarting the Exchange OV/VM Connector clears the backlog.
CAUSE
The RSCS link definition for the Microsoft Exchange Server VM Node may be incorrectly configured for multiple threads. The Exchange OV/VM Connector supports only one thread.
RESOLUTION
Contact your local VM administrator, who has access to the host mainframe.
- Open the RSCS configuration file.
- Ensure that the STREAMS or ST parameter is set to 1. For example:
PARM RSCSLINK BUFF=3072 ST=1 TA=0
The default for RSCS communications between OV/VM systems is for multiple threads. - You must restart the RSCS system for any changes to take effect.
Modification Type: | Minor | Last Reviewed: | 4/28/2005 |
---|
Keywords: | kbprb KB240439 |
---|
|