SYMPTOMS

When you use the Visual Basic Editor (VBE) Source Code Control Add-in to manually check an object into Microsoft Visual SourceSafe before a previous check-in is complete, the Source Code Control Results and the Check Files into Visual SourceSafe dialog boxes may begin to flicker rapidly. The dialog boxes continue to flicker until you get a message that indicates that your system resources are low.

RESOLUTION

To stop the flickering, switch to another application window, and then back to the application you are working in.

Make sure that when you are checking multiple objects into Visual SourceSafe, you wait for one check-in to be completed before you start the next check-in.

STATUS

Microsoft has confirmed that this is a problem in the Microsoft products that are listed at the beginning of this article.

MORE INFORMATION

Steps to Reproduce the Behavior

  1. Add a VBA project containing at least two objects to Visual SourceSafe.
  2. Check out two of the objects, modify them, and then save your modifications.
  3. Check in one of the objects.
  4. Before the check-in in step 3 is completed, check in the second object.

    Note the flickering dialog boxes on your screen.
Check-ins typically happen very fast; therefore, reproducing this behavior depends on your timing and the speed of your processor.

Note that this problem does not apply to the Microsoft Access Source Code Control Add-in.

Modification Type:MajorLast Reviewed:6/25/2000